中国·永利y23455(股份)有限公司

EPC Products Sensing data acquisition Data Acquisition
SG-Link-200-OEM Wireless 2 Channel Analog Input Node
Date:2025-09-10 Views:88 Source:EPC

TC-Link-200-OEM

The TC-Link-200-OEM is a 1-channel wireless node used for precise measurement of temperature, mV, or resistance. No calibration is needed when used with thermocouples, RTD, or thermistors. The node will apply the appropriate linearization algorithms and CJC on-board based on the sensor type.


Sensor Input

  • 1 differential input channel

  • 1 single-ended input channel

  • 1 digital input for RPM or pulse counting

  • On-board temperature sensor (+/- 0.25°C)

  • 1.5 or 2.5 V sensor power output

  • Adjustable gain (1 to 128)

  • Adjustable filtering

  • High resolution 24-bit data

  • Noise as low as 1 µV p-p

  • Compatible with 120, 350, and 1kOhm Wheatstone bridge sensing circuits

  • Available factory bridge completion (¼, ½, or full-bridge)

  • Remote strain calibration using on-board shunt resistor

Operation

  • Up to 1 kHz continuous sampling rate

  • Continuous, periodic burst, or event-triggered operation

  • Output waveform data and/or derived parameters (Mean, RMS, peak-peak)

  • LXRS protocol allows lossless data collection, scalable network size, and node synchronization of ±50 µs

  • Datalogging up to 8 million data points

  • Wireless range up to 1km

  • Duty cycle sensor excitation for low power operation, well-suited for battery powered applications

Package

  • Power with 3.3 to 30 VDC

  • –40 to +105 °C operating temperature range

  • Humiseal 1B31 Conformal Coating

  • 4 mounting holes sized for 2-56 UNC

  • Optional aluminum base and sensor terminal

  • Antenna options include on-board, or U.FL connector


XML 地图
XML 地图