OIL-BASED HYDRAULIC SYSTEMS
|
|||
PRODUCT
NUMBER |
CONTAINER SIZE
|
SUGGESTED
DILUTION RATIO |
|
FSOG-250
|
250 ml (8.5 oz) bottle
|
0.62 L (21 oz) of additive per 1,000 L (264.17 gal) of oil-based hydraulic fluid
|
|
FSOG-500
|
500 ml (17.0 oz) bottle
|
||
FSOG-1L
|
1 liter (33.8 oz) bottle
|
||
FSOG-1G
|
3.8 liters (1 gallon) container
|
||
FSOG-5G
|
18.9 liters (5 gallons) container
|
||
FSOG-55G
|
208.2 liters (55 gallons) drum
|
||
FSOG-1T
|
1,000 liters (264.2 gallons) tote
|
||
WATER-BASED HYDRAULIC SYSTEMS
|
|||
PRODUCT
NUMBER |
CONTAINER SIZE
|
||
FSWG-250
|
250 ml (8.5 oz) bottle
|
Addition to oil-in-water emulsions (to be diluted)
When adding FluidSafe WB to a concentrated oil-inwater emulsion before dilution, the correct amount of FluidSafe WB needed will depend on the final percentage of emulsion that will be in the equipment once it has been diluted with water. To calculate the correct ratio of FluidSafe WB to add into an emulsion concentrate before dilution, divide 0.3 by the final concentration of emulsion when it is mixed with water. In the formula below, “E” represents the final percentage concentration of emulsion in the application solution:
(%FluidSafe WB) = (0.3/E) %
For example, if an emulsion concentrate is to be used at a 2% ratio in water, replace “E” with “2” and calculate the ratio, in this case (%FluidSafe WB) = (0.3/2) %, a 0.15% concentration. If adding to 1,000 liters of concentrate at this ratio, then 1.5 liters (0.15%) of FSWB would be required.
Additon to filled systems (with diluted emulsion or water)
The correct treatment ratio for fluid in working equipment is 0.0042% (0.042 liters FluidSafe WB per 1000 liters of working fluid).
|